The Quick-30 is the latest in mobile EEG technology, offering an unmatched level of usability and signal quality to enable new research applications. With the Quick-30 system, EEG signals can be obtained on most subjects in just under one or two minutes. The headset positions 30 active electrodes in an extended 10-20 array.
Measuring EEG signals in real-world environments is tough. Unlike a controlled laboratory environment, electrical noise from power lines, computers and other devices can easily overwhelm a conventional, unshielded EEG system. In addition, subject movements can also easily induce large amplitude electrical and physical noise to overwhelm the tiny EEG signal. To make real-world EEG acquisition, possible, the Quick-20 uses a highly optimized combination of sensors, mechanics and electronics to eliminate unwanted artifacts.
Combination of active electrodes and active shielding
Resistant against electrical and movement artifacts
Real-time measurement of sensor impedance
Research-quality EEG amplifier: 24-bit ADC, low-noise, high dynamic range inputs with flexible configuration of sample rates, bandwidth and channels
The Quick-30 is a complete portable EEG system in a wearable, lightweight package. Data can easily be streamed wirelessly via Bluetooth or recorded to a microSD card.
Low-noise dry electrodes that require minimum prep and no clean-up
Fully wireless: no cords for data recording or triggering
Comfortable without any restrictions on subject movement
Lightweight and wearable
Like all Cognionics, the Quick-30 is designed to interface with all of the hardware and software tools necessary for advanced neuroscience research.
Wireless triggering for precision timing and event marking
Extension support for additional sensor inputs, including respiration, ECG, GSR and more
Compatibility with a variety of third party analysis tools including EEGLAB/BCILAB, OpenVibe, Brain Vision Analyzer and more
Full access to raw data via real-time streaming API
Channel Count | 30 (extended 10-20) plus two optional referential leads | ||
Extension Channels | 8 optional analog inputs with add-on module for ECG/EMG/respiration/GSR, etc. | ||
Sensor Type | Active dry electrodes with local active shielding | ||
Impedance Monitoring | Real-time with EEG acquisition | ||
Bandwidth | 0-131 Hz at 500 samples/sec, 0-262 Hz at 1,000 samples/sec | ||
Sampling Rate | 500 or 1000 samples/sec | ||
Resolution | 24 bits per sample | ||
Noise | 0.7 µV RMS from 1-50 Hz, shorted inputs | ||
Wireless | Bluetooth, optimized for high speed | ||
Storage | microSD and microSDHC | ||
Motion Sensing | 3-axis Accelerometer, each axis an additional channel | ||
Power Supply | Dual hot-swappable lithium ion batteries, 8-hours wireless, 16-hours microSD | ||
Triggering | Compatible with Cognionics wireless trigger |
Live demonstration at SfN 2016 showing the headset's mobility, resistance to motion artifacts and robust wireless streaming capabilities, even in a crowded conference environment.
Real-time data streaming into Neuropype (by Qusp) showing sLoreta source reconstruction.
The Quick-20 is the latest in mobile EEG technology, offering an unmatched level of usability and signal quality to enable new research applications. With the Quick-20 system, EEG signals can be obtained on most subjects in just under one or two minutes. The headset, which supports the full 10-20 array, adapts to most older child and adult head sizes is easy to apply with a minimum of adjustments.
Measuring EEG signals in real-world environments is tough. Unlike a controlled laboratory environment, electrical noise from power lines, computers and other devices can easily overwhelm a conventional, unshielded EEG system. In addition, subject movements can also easily induce large amplitude electrical and physical noise to overwhelm the tiny EEG signal. To make real-world EEG acquisition, possible, the Quick-20 uses a highly optimized combination of sensors, mechanics and electronics to eliminate unwanted artifacts.
Combination of active electrodes and active shielding
Resistant against electrical and movement artifacts
Real-time measurement of sensor impedance
Research-quality EEG amplifier: 24-bit ADC, low-noise, high dynamic range inputs with flexible configuration of sample rates, bandwidth and channels
The Quick-20 is a complete portable EEG system in a wearable, lightweight package. Data can easily be streamed wirelessly via Bluetooth or recorded to a microSD card.
Low-noise dry electrodes that require minimum prep and no clean-up
Fully wireless: no cords for data recording or triggering
Comfortable without any restrictions on subject movement
Lightweight and wearable
Like all Cognionics, the Quick-20 is designed to interface with all of the hardware and software tools necessary for advanced neuroscience research.
Channel Count | Full 10-20 EEG array (20-channels plus reference and ground), plus 2 optional referential lead wires | ||
Extension Channels | 8 optional analog inputs with add-on module for ECG/EMG/respiration/GSR, etc. | ||
Sensor Type | Active dry electrodes with local active shielding | ||
Impedance Monitoring | Real-time with EEG acquisition | ||
Bandwidth | 0-131 Hz at 500 samples/sec, 0-262 Hz at 1,000 samples/sec | ||
Sampling Rate | 500 or 1000 samples/sec | ||
Resolution | 24 bits per sample | ||
Noise | 0.7 µV RMS from 1-50 Hz, shorted inputs | ||
Wireless | Bluetooth, optimized for high speed | ||
Storage | microSD and microSDHC | ||
Motion Sensing | 3-axis Accelerometer, each axis an additional channel | ||
Power Supply | Dual hot-swappable lithium ion batteries, 8-hours wireless, 16-hours microSD | ||
Triggering | Compatible with Cognionics wireless trigger |
System Introduction
Using Neuroguide for Neurofeedback and QEEG (Old Model)
P300 Speller using OpenViBE
The Cognionics Multi-position Headband is a designed to be a simple, flexible dry EEG experimental platform. The system is intended for use with our research grade Miniature Wireless EEG Data Acquisition System, Flex and Drypad sensors to provide low-noise, reliable dry electrode recordings.
The headband is fully reconfigurable for different experiments and applications. Sensors can be attached and moved to any of the 12 positions along the circumference of the headband to measure signals from the frontal, occipital and temporal regions. A highly elastic fabric ensure comfort, fit across a wide variety of head sizes and provides contact pressure for the dry electrodes.
Specifications
Channel Count | 2-8 channels can be placed in any of 14 positions along the band | ||
Extension Channels | Optional add-on module for ECG/EMG/EOG/Respiration/GSR/etc. | ||
Impedance Check | Continuous, real-time monitoring of all channels simultaneous with EEG | ||
A/D Resolution | 24-bit simultaneous sampling analog-to-digital converters | ||
Sampling Rate | 500 Hz standard, 250-1000 Hz configurable | ||
Bandwidth | 0 - 130 Hz, true DC coupling | ||
Storage | microSD and microSDH | ||
Triggering | Compatible with Cognionics wireless trigger | ||
Weight | 120 g |
For detailed information regarding the electronics, please refer to the Miniature Wireless EEG Data Acquisition System
Dry EEG Headband
Light, portable and easy-to-wear
Put it on in less than a minute, wear it for hours
Dry sensors work through hair
The Headband is a compact mobile EEG system that's designed to be lightweight and easy to use. A soft fabric encloses all of the electronics thereby eliminating loose wires. The headband is completely elastic making it easy to put on and wear. With the flexible dry electrode, the Headband can be configured with anywhere from 2 to 8 channels along the circumference of the head, even through hair. It uses the same research quality (24-bit) wireless EEG electronics as our high density headset.
{youtube}mxJnrJoQ694|600|450|0{/youtube}
Click here for full spec sheet
Click here for description of included software
Contact us for more information
Dry Sleep EEG Headband
Sleep System - Designed for Real-World Studies
Dry - Mobile - Wireless
Fast Application, Comfortable and wearable
No Gels or Cleanup, Conformable with minimal simple adjustments
High Signal Quality
Specifications
Channel Count | 2-8 channels can be placed in any of 14 positions along the band | ||
Extension Channels | Optional add-on module for ECG/EMG/EOG/Respiration/GSR/etc. | ||
Impedance Check | Continuous, real-time monitoring of all channels simultaneous with EEG | ||
A/D Resolution | 24-bit simultaneous sampling analog-to-digital converters | ||
Sampling Rate | 500 Hz standard, 250-1000 Hz configurable | ||
Bandwidth | 0 - 130 Hz, true DC coupling | ||
Storage | microSD and microSDHC | ||
Triggering | Compatible with Cognionics wireless trigger | ||
Weight | 110 g |
August 17, 2017
Cognionics moves to new 8,000 square foot facility at 8445 Camino Santa Fe Drive, Suite 104.
August 8, 2017
Cognionics awarded grant to work on unobtrusive neurotechnology and HCI for enhanced learning.
June 26, 2017
New demonstration! Our new video in the "Videos" page shows how quickly our headsets recover from rTMS.
June 6, 2017
Cognionics selected for Phase II STTR to develop a circadian rhythm monitoring device
December 23, 2016
Cognionics selected for Phase I STTR to develop a stress/strain monitoring device
November 15, 2016
Introducing the New Quick-30 Dry EEG Headset
November 15, 2016
Introducing the 2nd Generation Quick-20 Dry EEG Headset